The instrument is designed and made as per ASTM D 1744. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.
Specification :
Technical parameters
1. Titration mode: Coulometric titration controlled by a microprocessor
2. Measurement range: 1μg~100mg (Representative value: 10μg~10mg)
3. Electrolysis control: Automatic electrolysis current control (Max is 400 mA)
4. Titration speed: 2 mg/min (Maximum)
5. Test accuracy: 10μg~1mg±3μg, It will be 0.3% for more than 1 mg (not including sample filling error)
6. End point: information display, buzzer alarm, and indication light is on
7. Date: Year Month Day Hour Minute Second
8. Printer: 16 characters width pin-printer. Paper width is 44 mm,
9. Power supply: AC 220V±10%, 50Hz±5%
10. Power: 60 W
11. Ambient temperature: 5~40°C
12. Relative humidity: ≤90%
13. Size: 290×380×120 (mm)
14. Weight: 9 Kg
Ultra-Sensitive Moisture Analysis with the Trace Moisture Meter DWC-212 (Automatic Karl Fischer Titrator)
Achieve unparalleled accuracy in trace-level water determination with the Trace Moisture Meter DWC-212—a fully automated Karl Fischer (KF) Coulometric Titrator engineered for pharmaceuticals, petrochemicals, specialty chemicals, and battery materials. Capable of detecting moisture from 1 µg to 10 mg H₂O (equivalent to 0.1 ppm to 100%), the DWC-212 delivers laboratory-grade precision for applications where even minute water content impacts product stability, safety, or performance.
Engineered for Precision, Automation, and Compliance
The DWC-212 Trace Moisture Meter uses coulometric Karl Fischer titration, the gold standard for trace moisture analysis, to generate iodine electrochemically and measure water content with exceptional sensitivity. Its sealed, dual-chamber titration cell minimizes atmospheric moisture interference, while the intelligent algorithm automatically detects endpoint stability, calculates results, and validates data integrity—fully compliant with USP <921>, EP 2.5.12, ASTM E1064, and ISO 760.
- Ultra-Low Detection Limit: 1 µg H₂O (0.1 ppm) – Ideal for dry solvents, APIs, lithium salts, and transformer oil.
- Fully Automatic Operation – Auto-titration, drift compensation, endpoint detection, and result calculation.
- Dual-Platinum Electrode System – Ensures stable baseline and rapid response for high repeatability.
- Large Color Touchscreen Interface – Intuitive method setup, real-time titration curve, and GLP-compliant audit trail.
- Data Management & Connectivity – USB, RS232, and optional printer support; exports to CSV or LIMS.
- Integrated Reagent Status & Maintenance Alerts – Monitors anolyte/catholyte life and cell cleanliness.
Trusted in Regulated and High-Stakes Industries
From verifying moisture in lithium battery electrolytes and pharmaceutical excipients to ensuring dryness in high-purity solvents or gas streams, the DWC-212 replaces manual, error-prone methods with a robust, traceable solution. Its compact footprint fits in any QC lab, and its compliance-ready design supports GMP, ISO 17025, and FDA 21 CFR Part 11 documentation requirements.
When water content determines shelf life, reactivity, or safety—precision isn’t optional.
Choose the Trace Moisture Meter DWC-212 for confidence in every microgram.